Customization: | Available |
---|---|
Type: | Infrared Gas Sensor |
Conductivity Type: | Surface Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical Specifications | |||
MEASUREMENT | |||
Operating Principle | 3-electrode electrochemical | ||
Detection Range | 0~100 ppm | ||
Sensitivity | 200 ± 100 nA /ppm | ||
Response Time (T90) | ≤50 s | ||
Repeatability | <±2% signal | ||
Linearity | Linear | ||
Long term output Drift | <2% signal/month | ||
ELECTRICAL |
|||
Resolution | 0.5 ppm | ||
Recommended Load | 5~10 | ||
Bias Voltage | +300mV | ||
ENVIRONMENTAL |
|||
Operating Temp. Range | -40°C ~ 50°C | ||
Operating Humidity Range | 15% RH ~ 95% RH non-condensing | ||
Operating Pressure Range | 800 ~ 1200 mbar | ||
LIFETIME |
|||
Recommended Storage Temp. | 0°C to +20°C in sealed container | ||
Expected Operating Life | 24 months in air | ||
Storage Life | 6 months in original packaging | ||
Standard Warranty | 12 months from date of despatch |
Cross-sensitivity Data | ||
Gas | Concentration(ppm) | Output signal (ppm CH3OH equivalent) |
Carbon monoxide | 20 | 8.5 |
Carbon dioxide | 1000 | 0.0 |
Carbonyl sulfide | 20 | 10.9 |
Hydrogen sulfide | 20 | 12.3 |
Sulfur dioxide | 20 | 6.7 |
Methyl mercaptan | 10 | 6.8 |
Methane | 5000 | 0.0 |
Tetrachloromethane | 50 | 0.0 |
Arsine | 10 | 2.1 |
Ammonia | 50 | -4.6 |
Chlorine | 100 | -5.8 |
Hydrogen | 1000 | 2.6 |
Nitric oxide | 10 | 11.8 |
Nitrogen dioxide | 10 | 4.8 |