Customization: | Available |
---|---|
Type: | Infrared Gas Sensor |
Conductivity Type: | Surface Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical Specifications | ||
MEASUREMENT | ||
Operating Principle |
|
|
Detection Range | 0~100000 ppm | |
Filter | To remove acid gases (such as SO2, NO, NO2, Cl2& H2S) |
|
Filter Capacity | >1500000 ppm hours | |
Sensitivity | 1 ± 0.5 nA/ppm | |
Response Time (T90) | ≤40 s | |
Repeatability | <±2% signal | |
Linearity | Linear | |
Long term output Drift | <2% signal/month | |
ELECTRICAL | ||
Resolution | 1 ppm | |
Recommended Load | 5~35 | |
Bias Voltage | 0 mV | |
ENVIRONMENTAL |
||
Operating Temp. Range | -20°C ~ 50°C | |
Operating Humidity Range | 15% RH ~ 90% RH non- condensing | |
Operating Pressure Range | 800 ~ 1200 mbar | |
LIFETIME |
||
Recommended Storage Temp. | 0°C to +20°C in sealed container | |
Expected Operating Life | 24 months in air | |
Storage Life | 6 months in original packaging | |
Standard Warranty | 12 months from date of despatch |
Sensitivity Temperature Dependence Cross-sensitivity Data |
||
Gas | Concentration(ppm) | Output signal (ppm CO Hydrogen equivalent) |
Hydrogen Sulfide | 2500 | 0 |
Sulfur Dioxide | 1000 | 0 |
Chlorine | 800 | 0 |
Nitric Oxide | 2000 | 0 |
Nitrogen Dioxide | 1000 | 0 |
Hydrogen | 10000 | 0 |